• Product Description |
Status |
Active |
Article number |
3618-0001 |
Ports |
1 x Public Switched Telephone Network (PSTN)
1 x Leased Line (LL)
1 x RS-422/485
1 x RS-232 |
Description |
Industrial backup PSTN
and Leased Line Modem |
•Standard compliance |
PSTN |
CS 03 Part 1, issue 9
FCC part 68, TIA-968-A
ETSI TS103 021-1, ETSI TS103 021-2, ETSI TS103 021-3
AS/ACIF S002, AS/ACIF S006 |
• Reliability prediction |
Service life, operating |
Operating, 10 years |
• EMC (Electromagnetic Compatibility) |
EN 55024 |
Immunity IT equipment |
EN 55022 |
Emission IT equipment |
EN 61000-6-1 |
Immunity residential environments |
EN 61000-6-2 |
Immunity industrial environments |
EN 61000-6-4 |
Emission industrial environments |
FCC part 15 |
Class A |
EN 50121-4 |
Railway signalling and telecommunications apparatus |
IEC 62236-4 |
Railway signalling and telecommunications apparatus |
• EMC Specification |
EN 61000-4-2, ESD |
Enclosure contact, ± 6 kV
Enclosure air, ± 8 kV |
IEC 61000-4-3, RF field AM modulated |
Enclosure:
20 V/m @ (80 – 2700) MHz
1 kHz sine, 80% AM |
ENV 50204, RF field 900 MHz |
Enclosure, 20 V/m pulse modulated 200 Hz, 900 ± 5 MHz |
EN 61000-4-4, fast transients |
Signal ports, ± 2 kV
Power ports, ± 2 kV |
EN 61000-4-5, surge |
Signal ports unbalanced, ± 2 kV line to earth, ± 2 kV line to line
Signal ports balanced, ± 2 kV line to earth, ± 1 kV line to line
Power ports, ± 2 kV line to earth, ± 2 kV line to line |
EN 61000-4-6, conducted RF immunity |
Signal ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz |
EN 61000-4-11, Voltage dips and interruption |
AC power ports:
10 & 5 000 ms, interruption
10 & 500 ms, 30% reduction
100 & 1 000 ms, 60% reduction |
EN 61000-4-16, Mains freq. 50 Hz |
Signal ports, 100 V 50 Hz line to earth |
EN 61000-4-29, voltage dips and interruption |
DC power ports:
10 & 100 ms, interruption
10 ms, 30% reduction
10 ms, 60% reduction
+20% above & –20% below rated voltage |
EN 55022, radiated RF emission |
Enclosure, Class A |
FCC part 15, radiated RF emission |
Enclosure, Class A |
EN 55022, conducted emission |
AC power ports, class B
PSTN, class B
DC power ports, class B |
FCC part 15, conducted emission |
AC power ports, Class B |
• Safety |
EN 60950-1,dielectric strength |
Signal port to other isolated ports, 2 kVrms 50 Hz 1 min
Power port to other isolated ports:
3 kVrms 50 Hz 1 min
2 kVrms 50 Hz 1 min (@ rated power <60 V) |
• Climatic |
Temperature, operating |
–25 to +70°C (–13 to +158°F) |
Temperature, storage |
–40 to +70°C (–40 to +158°F) |
Humidity, operating |
5 to 95% relative humidity non condensing |
Humidity, storage |
5 to 95% relative humidity non condensing |
• Enclosure |
Enclosure |
UL 94, PC / ABS, flammability class V-1 |
Dimensions (W x H x D) |
55 x 100 x 132 mm (2.16 x 3.93 x 5.19 in) |
Weight |
0.36 kg |
Degree of protection |
IP 20 |
Cooling |
Convection |
Mounting |
Horizontal on 35 mm DIN-rail |
• Mechanical |
IEC 60068-2-6, vibration |
Operating
7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz |
IEC-60068-2-27, shock |
Operating, 15 g, 11 ms |
• Interface specifications, power |
Operating voltage |
18 to 300 VDC
22 to 264 VAC |
Rated voltage |
20 to 250 VDC
24 to 240 VAC |
Rated current |
125 mA @ 18 VDC
15 mA @ 110 VDC
8 mA @ 250 VDC
120 mA @ 22 VAC
35 mA @ 95 VAC
28 mA @ 240 VAC |
Rated frequency |
DC: –
AC: 48 – 62 Hz |
Inrush current |
0.45 A²s |
Startup current |
0.25 Apeak |
Polarity |
Polarity independent |
Isolation to |
All other ports 3 kVrms 50 Hz 1 min |
Connection |
Detachable screw terminal |
Connector size |
0.2 – 2.5 mm2 (AWG 24-12) |
Shielded cable |
Not required |
• Public Switched Telephone Network(PSTN) |
Electrical specification |
Public Switched Telephone Network |
Data rate |
300 bit/s – 33.6 kbit/s |
Protocol |
B103, B212, V21, V22, V22B, V23C, V23 HDX, V32, V32B, V34 |
Protection |
Installation Fault Tolerant (up to ±60 V) |
Isolation to |
Power port, 3 kVrms 50 Hz 1 min
Leased Line, 2 kVrms 50 Hz 1 min
RS-232, 2 kVrms 50 Hz 1 min
RS-485, 2 kVrms 50 Hz 1 min
I/O, 2 kVrms 50 Hz 1 min |
Connection |
RJ-11C and Detachable screw terminal |
Connector sixe |
Detachable screw terminal 0.2 – 2.5 mm² (AWG 24 – 12) |
Shielded cable |
Not required |
• Interface specification, Leased line |
Electrical specification |
2- or 4-wire Leased Line |
Data rate |
300 bit/s – 33.6 kbit/s |
Protocol |
B103, B212, V21, V22, V22B, V23C, V23 HDX, V32, V32B, V34 |
Transmission range |
PSTN 30 dB |
Budget |
Leased Line max 40 dB |
Protection |
Installation Fault Tolerant (up to ± 60 V) |
Isolation to |
Power port, 3 kVrms 50 Hz 1 min
Leased Line, 2 kVrms 50 Hz 1 min
RS-232, 2 kVrms 50 Hz 1 min
RS-485, 2 kVrms 50 Hz 1 min
I/O, 2 kVrms 50 Hz 1 min |
Connection |
Detachable screw terminal |
Connector size |
0.2 – 2.5 mm² (AWG 24 – 12) |
Shielded cable |
Not required |
• Interface specifications, RS-232 |
Electrical specification |
EIA/TIA-232 |
Data rate |
300 bit/s – 115.2 kbit/s |
Data format |
7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits.
9-12 bit words |
Protocol |
Transparent |
Retiming |
Yes |
Transmission range |
Cable length ≤ 15 m |
Galvanic connection to |
RS-485 |
Isolation to |
Power port, 3 kVrms 50 Hz 1 min
PSTN Line, 2 kVrms 50 Hz 1 min
Leased Line, 2 kVrms 50 Hz 1 min
I/O, 1.5 kVrms 50 Hz 1 min |
Connection |
9-pin D-sub female (DCE)
and Detachable screw terminal (DCE ) |
Shielded cable |
Not required |
Connector size |
Detachable screw terminal 0.2 – 2.5 mm2 (AWG 24 – 12) |
Miscellaneous |
Do not connect RS-232 and RS-422/485 simultaneously |
• Interface specifications, RS-422/485 |
Electrical specification |
EIA/TIA-485 ITU V.11
2-wire or 4-wire twisted pair |
Data rate |
300 bit/s – 115.2 kbit/s |
Data format |
7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits.
9-12 bit words |
Protocol |
Transparent |
Retiming |
Yes |
Turning time |
<10 μs (half duplex) |
Transmission range |
≤ 1200 m, depending on data rate and cable type (EIA RS-485) |
Settings |
120 Ω termination and failsafe biasing 680 Ω |
Protection |
Installation Fault Tolerant (up to ±60 V) |
Galvanic conection to |
RS-232 |
Isolation to |
Power port, 3 kVrms 50 Hz 1 min
PSTN Line, 2 kVrms 50 Hz 1 min
Leased Line, 2 kVrms 50 Hz 1 min
I/O, 1.5 kVrms 50 Hz 1 min |
Connection |
Detachable screw terminal |
Connector size |
0.2 – 2.5 mm2 (AWG 24 – 12) |
Shielded cable |
Not required |
Miscellaneous |
Do not connect RS-232 and RS-422/485 simultaneously |
• Interface specification, I/O / Digital input |
Electrical specification |
Opto isolated input |
Input voltage range |
0 – 60 VDC |
Input current |
5 mA @ 60 VDC |
Input inactive |
Uin < 2.5 V |
Input active |
Uin >5.0 V |
Transmission range |
Cable length ≤ 15 m |
Connection |
Detachable screw terminal (DCE) |
Connector size |
0.2 – 2.5 mm² (AWG 24 – 12) |
Isolation to |
Power port, 3 kVrms 50 Hz 1 min
PSTN line, 2 kVrms 50 Hz 1 min
Leased Line, 2 kVrms 50 Hz 1 min
RS-232, 2 kVrms 50 Hz 1 min
RS-485, 2 kVrms 50 Hz 1 min
I/O, output 2 kVrms 50 Hz 1 min |
Shelded cable |
Not required |
• Interface spcification, I/O relay output |
Electrical specification |
One change over contact |
Switching voltage |
Max 40 V AC/DC |
Switching current |
Max 500 mA AC/DC |
Electrical endurance |
5 x 10^5 operations at 20 W / 20 VA Resistive load |
Transmission range |
Cable length ≤ 15 m |
Connection |
Detachable screw terminal (DCE) |
Connector size |
0.2 – 2.5 mm² (AWG 24 – 12) |
Shielded cable |
Power port, 3 kVrms 50 Hz 1 min
PSTN line 2, kVrms 50 Hz 1 min
Leased Line, 2 kVrms 50 Hz 1 min
RS-232 1.5, kVrms 50 Hz 1 min
RS-485 1.5, kVrms 50 Hz 1 min
I/O, input 2 kVrms 50 Hz 1 min |
Shielded cable |
Not required |