The PE1216 Energy PDU contains 16 AC outlets and is available in IEC or NEMA socket configurations. The PE1216 Energy PDU features a space-saving 0U design that allows it to be mounted vertically on the outside of a rack, resulting in a more efficient use of space in the server room, while providing 16 AC outlets.The PE1216 Energy PDU can be integrated into an installation with the EC1000 Energy Box*, allowing you to monitor the real-time current and environmental conditions of the Energy PDU from the front panel of the EC1000 at the rack, or via Web GUI remotely – making your server room efficiently green with ease.
Connections
• Support 10/100Mbit Ethernet Interface
• Support TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, NTP, DNS, Auto Sense, Ping, SNMP V1,V2&V3
• Support 2-level account/password security, IP/MAC filter, 128 bit SSL, RADIOUS
• Support : eco Sensors, Browser ( IE, Firefox, Chrome, Safari )
Metering
• PDU and outlet level power metering and monitoring
• Environment monitoring – supports external temperature/temperature & humidity sensors for rack temperature and humidity monitoring
• Current, voltage, power, power dissipation, temperature, and humidity metering and threshold level setting
• Support door sensor
Outlet Switch Control
• Remote power outlet control (On/Off, Power Cycle) by individual outlets and outlet groups
• Outlet group support at the PDU level
• Supports multiple power control methods – Wake on LAN, System After AC Back, Kill the Power
• Power-On sequencing, users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the
correct order
• Critical load outlet – keeps power always on for critical load devices
• Proactive overload protection(POP) – automatically powers off the last outlet that caused the current overload
Note:
Function | PE9330B |
Electrical |
|
Nominal Input Voltage | 100 – 240 VAC |
Maximum Input Current | 30A Max ; 24A (UL de-rated) |
Input Frequency | 50-60 Hz |
Input Connection | NEMA L6-30P |
Input Power | 6240 VA(Max) 4992 VA (UL de-rated) |
Outlet Type | Total : 26 x IEC320 C13 + 4 x IEC320 C19 Bank1-1 : Outlet 1 – 14 ; 12 x C13 + 2 x C19 Bank1-2 : Outlet 15 – 22 ; 7 x C13 + 1 x C19 Bank2 : Outlet 23 – 30 ; 7 x C13 + 1 x C19 |
Nominal Output Voltage | 100 – 240 VAC |
Maximum Output Current (Outlet) | C13 : 15A (Max) 12A(UL de-rated) C19 : 15A (Max) 12A(UL de-rated) |
Maximum Output Current (Bank) | 15A(Max) 12A (UL de-rated) |
Maximum Output Current (Total) | 30A(Max) 24A (UL de-rated) |
Breakers | 2 x 16A UL489 Breaker |
Metering | Per Outlet Level Current, Voltage, VA, PF, KWh Monitoring |
Outlet Switch | Bank1-1 : None Bank1-2 : Yes Bank2 : Yes |
Environment Sensor Port | 4 |
Metering Accuracy | Voltage Range: 100VAC ~ 250VAC +/-1% Power Range: 100W ~ 5000W +/- 2% Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1% |
Mechanical |
|
Dimension (H x W x D) | 69.9 x 2.6 x 1.7 in. (177.5 x 6.6 x 4.4 cm) |
Shipping Dimensions ( H x W x D) | 74.4 x 8.3 x 6.7 in. (189 x 21 x 17 cm) |
Weight/Shipping Weight | 14.1 / 22.9 lb. (6.4 / 10.4 kg) |
Power Cord Length | 5 feet (1.6 m) |
Environmental |
|
Temperature (Operating / Storage) | 0 – 50°C / -20 – 60°C |
Humidity (Operating & Storage) | 0 – 80% RH, Non-Condensing |
Compliance |
|
EMC Verication | FCC Part 15 Class A, Others by Reuest |
Safety Verication | TUV-CB, Others by Reuest |
* The specification and pictures are subject to change without notice.