As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (eco PDUs) to effectively increase the efficiency of data center power usage. The NRGence PE8324r eco PDUs are intelligent PDUs that contain 24 AC outlets and are available in various IEC or NEMA socket configurations.

Connections
• Supports 10/100Mbit Ethernet, Modem, RS-232, Daisy Chain interface

• Supports TCP/IP, PPP, UDP, HTTP, HTTPS, SSL, STP, DCHP, ARP, NTP, DNS, Telnet, Auto Sense, Ping, SNMP V1,V2&V3, IPv6

• Supports three-level account/password security, IP/MAC filter, 128 bit SSL, RADIUS, TACACS+, LDAP, LDAPS and Active Directory

• Supports CC2000, eco Sensors, Java API, multiple Browsers (IE, Firefox, Chrome, Safari), OOBC/RS232

Metering
• PDU and outlet level power metering and monitoring

• Environment monitoring – supports external temperature/temperature & humidity sensors for rack temperature and humidity monitoring

• Current, voltage, power, power dissipation, temperature, and humidity metering and threshold level setting

Outlet Switch Control
• Remote power outlet control (On/Off, Power Cycle) by individual outlets and outlet groups

• Outlet group support at the PDU and daisy chain level

• Daisy chain with PON In – PON Out port

• On/Off scheduling for individual outlets and outlet groups,power management tasks can be scheduled on a daily,weekly,monthly,
or user-specified basis

• Supports multiple power control methods – Wake on LAN, System After AC Back, Kill the Power

• Power-On sequencing, users can set the power-on sequence and delay time for each outlet to allow equipment to be powered on in the
correct order

Function  PE8324A  PE8324B  PE8324G

 Electrical

 Nominal Input Voltage  100 – 120 VAC  100 – 240 VAC  100 – 240 VAC
 Maximum Input Current  30A(Max); 24A(UL de-rated)  30A Max; 24A (UL de-rated)  32A Max
 Input Frequency  50-60 Hz  50-60 Hz  50-60 Hz
 Input Connection  NEMA L5-30P  NEMA L6-30P  IEC 60309 32A
 Input Power  6240 VA(Max); 4992 VA(UL de-rated)  6240 VA(Max); 4992 VA(UL de-rated)  7360 VA(Max)
 Outlet Type  Total: 24 x NEMA 5-15R
Bank1-1: Outlet 1 – 8; 8 x NEMA  5-15R
Bank1-2: Outlet 9 – 16; 8 x NEMA 5-15R
Bank2: Outlet 17 – 24; 8 x NEMA 5-15R
 Total: 21 x IEC320 C13 + 3 x IEC320 C19
Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19
Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19
Bank2: Outlet 17 – 24; 7 x C13 + 1 x C19
 Total: 21 x IEC320 C13 + 3 x IEC320 C19
Bank1-1: Outlet 1 – 8; 7 x C13 + 1 x C19
Bank1-2: Outlet 9 – 16; 7 x C13 + 1 x C19
Bank2: Outlet 17 – 24; 7 x C13 + 1 x  C19
 Nominal Output Voltage  100 – 120 VAC  100 – 240 VAC  100 – 240 VAC
 Maximum Output Current (Outlet)  NEMA 5-15R: 15A(Max); 12A(UL de-rated)  C13: 15A(Max); 12A(UL de-rated)
C19: 15A(Max); 12A(UL de-rated)
 C13: 10A(Max)
C19: 16A(Max); TUV De-rated 15A(Max)
 Maximum Output Current (Bank)  15A(Max); 12A(UL de-rated)  15A(Max); 12A(UL de-rated)  16A(Max); TUV De-rated 15A(Max)
 Maximum Output Current (Total)  30A(Max); 24A(UL de-rated)  30A(Max); 24A(UL de-rated)  32A(Max); TUV De-rated 30A(Max)
 Breakers  2 x 16A UL489 Breaker  2 x 16A UL489 Breaker  2 x 16A UL489 Breaker
 Metering  Outlet Level Current, Voltage, VA, PF, KWh Monitoring  Outlet Level Current, Voltage, VA, PF, KWh Monitoring  Outlet Level Current, Voltage, VA, PF, KWh Monitoring
 Outlet Switching  Yes  Yes  Yes
 Environment Sensor Ports  4  4  4
 Metering Accuracy  Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
 Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum  Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%
 Voltage Range: 100VAC ~ 250VAC +/-1%
Power Range: 100W ~ Maximum Capacity +/- 2%
Current Range: 0.1A~1A +/- 0.1A, 1A~20A +/-1%

 Physical Properties

 Dimensions (L x W x H)  177.50 x 6.60 x 4.40 cm
( 69.88 x 2.6 x 1.73 in.)
 177.50 x 6.60 x 4.40 cm
( 69.88 x 2.6 x 1.73 in.)
 177.50 x 6.60 x 4.40 cm
( 69.88 x 2.6 x 1.73 in.)
 Weight  6.33 kg ( 13.94 lb )  6.33 kg ( 13.94 lb )  6.33 kg ( 13.94 lb )
 Power Cord Length  1.6 m  1.6 m  1.6 m

 Environmental

 Temperature (Operating / Storage)  0 – 50°C / -20 – 60°C  0 – 50°C / -20 – 60°C  0 – 40°C / -20 – 60°C
 Humidity (Operating & Storage)  0 – 80% RH, Non-Condensing  0 – 80% RH, Non-Condensing  0 – 80% RH, Non-Condensing

 Compliance

 EMC Verification  FCC Part 15 Class A, Others by Request  FCC Part 15 Class A, Others by Request  CE, Others by Request
 Safety Verification  By Request  By Request  CE-LVD, Others by Request

* The specification and pictures are subject to change without notice.
* All trademarks and logos are the properties of their respective holders.

TOP