• Product Description |
Status |
Active |
Article number |
3641-0360 |
Ports |
8 x 10/100BaseTX, M12 contact |
Description |
Ultra slim M12 switch platform |
• EMC specifications |
EN 61000-4-2, ESD |
Enclosure contact, ± 6 kV (crit A)
Enclosure air, ± 8 kV (crit A) |
IEC 61000-4-3, RF field AM modulated |
Enclosure:
20 V/m 80% AM (1 kHz)
80 – 2500 MHz (crit A) |
EN 61000-4-4, fast transients |
Ethernet ports, ± 2 kV (crit A)
Power port, ± 2 kV (crit A)
Earth port, ± 2 kV (crit A) |
EN 61000-4-5, surge |
Fault port, ± 2 kV line to earth (crit A)
Ethernet ports, ± 2 kV line to earth (crit A)
Ethernet ports, ± 2 kV line to earth (crit A) |
EN 61000-4-6, conducted RF immunity |
Ethernet ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz (crit A)
Power port, 10 V 80% AM (1 kHz), 0.15 – 80 MHz (crit A) |
EN 61000-4-8, power frequency magnetic field |
Enclosure:
1000 A/m 50 Hz
300 A/m 16.7 Hz, 60 Hz, DC (crit A) |
EN 61000-4-9, pulsed magnetic field |
Enclosure, 300 A/m (crit A) |
EN-50155, voltage dips and interruption |
DC power ports:
10 ms, interruption (crit A)
100 ms +- 40 % above/below rated voltage (crit A) |
EN 55022, radiated RF emission |
Enclosure, Class B |
FCC part 15, radiated RF emission |
Enclosure, Class B |
EN 55022, conducted emission |
DC power port & Ethernet ports, Class B |
FCC part 15, conducted emission |
DC power port, Class B |
• EMC (Electromagnetic Compatibility) |
EN 61000-6-1 |
Immunity residential environments |
EN 61000-6-2 |
Immunity industrial environments |
EN 55024 |
Immunity IT equipment |
|
|
EN 61000-6-3 |
Emission residential environments |
EN 61000-6-4 |
Emission industrial environments |
|
|
EN-50121-3-2 |
Railway applications – EMC: Rolling stock – Apparatus |
FCC part 15 |
Class B |
EN 50121-4 |
Railway signalling and telecommunications apparatus |
IEC 62236-4 |
Railway signalling and telecommunications apparatus |
• Safety |
Safety |
EN 60950-1, IT equipment |
EN 60950-1, dielectric strength |
Ethernet ports to other isolated ports, 707 VDC 1 min |
• Reliability prediction |
MTBF, operating |
MIL-HDBK- 217F, operating:
Ground Benign:
103 years @ 20ºC
100 years @ 40ºC
90 years @ 60ºC
Ground Mobile:
5.92 years @ 20ºC
5.91 years @ 40ºC
5.88 years @ 60ºC |
Service life, operating |
Operating, 10 years |
• Climatic |
Temperature, operating |
–40 to +70°C (–40 to +158°F) |
Temperature, storage |
–40 to +70°C (–40 to +158°F) |
Humidity, operating |
5 to 95 % relative humidity |
Humidity, storage |
5 to 95 % relative humidity |
• Enclosure |
Enclosure |
UL 94, Nickel coated zinc, flammability class V-1 |
Dimensions (W x H x D) |
175 x 100 x 50 mm |
Weight |
0.8kg |
Degree of protection |
IP 65 when all ports are protected/connected else IP 40 |
Cooling |
Convection |
Mounting |
Wall mounted |
• Mechanical |
Vibration, random simulated long life |
Vertical: 7.9 m/s2
Transverse: 7.9 m/s2
Longitudinal: 7.9 m/s2
3 x 5 h |
Vibration, random functional |
Vertical: 1.0 m/s2
Transverse: 1.0 m/s2
Longitudinal: 1.0 m/s2
3 x 10 min |
Shock, half sine pulses |
Vertical: 50 m/s2
Transverse: 50 m/s2
Longitudinal: 50 m/s2
30 ms, 3 x 6 shocks |
Shock, sawtooth |
Vertical: 100 m/s2
Transverse: 100 m/s2
Longitudinal: 100 m/s
211 ms, 3 x 6 shocks |
• Interface specifications, power |
Operating voltage |
Up to 110 VDC |
Rated voltage |
24 to 110 VDC |
Rated current |
30 mA @ 110 VDC
90 mA @ 24 VDC |
Rated frequency |
DC |
Inrush current |
Max 0.02 A2s @ 24 – 110 VDC |
Startup current |
7 Apeak @ 24 – 110 VDC |
Polarity |
Reverse polarity protected |
Redundant power input |
No |
Isolation to |
Connections X1 – X8 and to ground, 1500 VAC.
Fault relay belongs to the same isolation group as the power supply lines (fault relay signals are also contained within PWR). |
Fault relay resistance |
< 10 Ω |
Connection |
4 pin male M12 connector with A-code |
Connector size |
M12, recommended cable area 0.5 mm2 recommended (minimum 0.25 mm2), cable dimensions depend on choice of M12 connector |
Shielded cable |
Not required, twisted pair is recommended |
Operating voltage |
Up to 110 VDC |
Max continuous current |
250 mA |
• Interface specifications, 10/100BaseTX |
Electrical specification |
IEEE std 802.3. 2005 Edition |
Data rate |
10 Mbit/s or 100 Mbit/s |
Duplex |
Full or half, manual or auto |
Circuit type |
TNV-1 |
Transmission range |
100 m / 328 ft |
Isolation to |
Other Ethernet ports, 500 VAC
PWR, 1500 VAC |
Galvanic connection to |
None, except for shielded contact to housing |
Connection |
4-pole M12 female with D-code |
Shielded cable |
Not required, twisted pair is recommended |
Conductive housing |
Nickel plated zinc, metal housings of X1-X8 also connected to the housing |
Number of ports |
8 Ethernet (X1-X8 |