Ports |
1 x 4-position detachable screw terminal, RS-422/485
1 x 9-pin D-sub, RS-232
1 x RJ-45, Ethernet |
Description |
Serial adapter |
• Approvals |
Hazardous locations |
EN 60079-0 and EN 60079-15 |
• Reliability prediction |
Service life, operating |
Operating, 10 years |
• EMC (Electromagnetic Compatibility) |
EN 61000-6-2 |
Immunity industrial environments |
EN 61000-6-4 |
Emission industrial environments |
EN 55024 |
Immunity IT equipment |
EN 50121-4 |
Railway signalling and telecommunications apparatus |
IEC 62236-4 |
Railway signalling and telecommunications apparatus |
• EMC Specification |
EN 61000-4-2, ESD |
Enclosure contact, ± 6 kV
Enclosure air, ± 8 kV |
IEC 61000-4-3, RF field AM modulated |
Enclosure:
20V/m 80% AM (1 kHz), 80 – 2 000 MHz
12V/m 80% AM (1 kHz), 2 000 – 2 700 MHz |
ENV 50204, RF field 900 MHz |
Enclosure, 20 V/m pulse modulated 200 Hz, 900 ± 5 MHz |
EN 61000-4-4, fast transients |
Signal ports, ± 2 kV
Power ports, ± 2 kV |
EN 61000-4-5, surge |
Signal ports unbalanced, ± 2 kV line to earth, ± 2 kV line to line
Signal ports balanced, ± 2 kV line to earth, ± 1 kV line to line
Power ports, ± 2 kV line to earth, ± 2 kV line to line |
EN 61000-4-6, conducted RF immunity |
Signal ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz |
|
|
EN 61000-4-9, pulsed magnetic field |
Enclosure, 1000 A/m, 6.4 / 16 µs pulse |
EN 61000-4-29, voltage dips and interruption |
DC power ports:
10 & 100 ms, interruption
10 ms, 30% reduction
10 ms, 60% reduction
+20% above & –20% below rated voltage |
EN 55022, radiated RF emission |
Enclosure, Class A |
FCC part 15, radiated RF emission |
Enclosure, Class A |
EN 55022, conducted emission |
DC power ports, Class B |
• Safety |
Safety |
UL/CSA/IEC/EN 60950-1, IT |
EN 60950-1,dielectric strength |
Signal port to other isolated ports, 1.5 kVrms 50 Hz 1 min
Power port to other isolated ports, 2 kVrms 50 Hz 1 min |
• Climatic |
Temperature, operating |
Operating, –25 to +70°C (–13 to +158°F) |
Temperature, storage |
Storage & Transport, –40 to +70ºC (–40 to +158ºF) |
Maximum surface temperature |
135ºC (temperature class T4) |
Humidity, operating |
Operating, 5 to 95% relative humidity |
Humidity, storage |
Storage & Transport, 5 to 95% relative humidity |
• Enclosure |
Enclosure |
UL 94, PC / ABS, flammability class V-1 |
Dimensions (W x H x D) |
34 x 123 x 121 mm (1.33 x 4.84 x 4.76 in) |
Weight |
0.2 kg |
Degree of protection |
IP 21 |
Cooling |
Convection |
Mounting |
Horizontal on 35 mm DIN-rail |
• Mechanical |
IEC 60068-2-6, vibration |
Operating:
7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz |
IEC-60068-2-27, shock |
Operating, 15 g, 11 ms |
• Interface specifications, power |
Operating voltage |
10 to 60 VDC |
Rated voltage |
12 to 48 VDC |
Rated current |
250 mA @ 12 VDC
125 mA @ 24 VDC
63 mA @ 48 VDC |
Rated frequency |
DC |
Inrush current |
0.3 A²s @ 48 VDC, @ 10 ms |
Startup current |
- |
Polarity |
Reverse polarity protected |
Redundant power input |
Yes |
Isolation to |
All other 2 k Vrms |
Connection |
Detachable screw terminal |
Connector size |
0.2 – 2.5 mm2 (AWG 24-12) |
Shielded cable |
- |
• Interface specifications, RS-422/485 |
Electrical specification |
EIA RS-485
2-wire or 4-wire twisted pair |
Data rate |
300 bit/s to 115.2 kbit/s |
Data format |
7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits |
Protocol |
Transparent, optimised by packing algorithm |
Retiming |
Not applicable |
Turning time |
< 3 bits- |
Circuit type |
TNV-1 |
Transmission range |
≤ 1200 m, depending on data rate and cable type (EIA RS-485) |
Settings |
120 Ω termination and fail-safe biasing 680 Ω |
Protection |
Installation Fault Tolerant (up to ±60 V) |
Isolation to |
Power: 2 kV
Ethernet: 1; 1.5 k Vrms |
Connection |
Detachable screw terminal |
Connector size |
0.2 – 2.5 mm² (AWG 24 – 12) |
Shielded cable |
Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails. |
Conductve housing |
No |
• Interface specifications, RS-232 |
Electrical specification |
EIA RS-232 |
Data rate |
300 bit/s – 115.2 kbit/s |
Data format |
7 or 8 data bits, Odd, even or no parity, 1 or 2 stop bits |
Protocol |
Transparent, optimised by packing algorithm |
Retiming |
Not applicable |
Circuit type |
SELV |
Transmission range |
15 m / 49 ft |
Conductive housing |
Isolated to all other circuits |
Isolation to |
Power 2 kV
Ethernet 1; 1.5 kVrms |
Connection |
9-pin D-sub male (DTE) |
Shielded cable |
Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails. |
Connector size |
Detachable screw terminal 0.2 – 2.5 mm2 (AWG 24 – 12) |
Number of ports |
1 |
• Interface specification, 10/100 BaseTX |
Electrical specification |
IEEE std 802.3. 2000 Edition |
Data rate |
10 Mbit/s or 100 Mbit/s, auto-negotiated or manually set by DIP-switches |
Protocol |
UDP, TCP, ICMP, HTTP and ARP |
Duplex |
Full- or half duplex, auto-negotiated or manually set by DIP-switches |
Circuit type |
TNV-1 |
Transmission range |
100 m |
Isolation to |
Power 2 kVrms
RS-232 1.5 kVrms
RS-422/485 1.5 kVrms |
Connection |
RJ-45 shielded, auto MDI/MDI-X |
Shielded cable |
Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails. |
Conductive housing |
Isolated to all other circuits |