• Product Description |
Status |
Active |
Article number |
3619-0001 |
Ports |
1 x RS-232
1 x RS-422/485
1 x ISDN |
Description |
Industrial ISDN Modem |
• Standard compliance |
ISDN |
TBR-3 |
• Reliability prediction |
Service life, operating |
Operating , 10 years |
• EMC (Electromagnetic Compatibility) |
EN 55024 |
Immunity IT equipment |
EN 55022 |
Emission IT equipment |
EN 61000-6-1 |
Immunity residential environments |
EN 61000-6-2 |
Immunity industrial environments |
EN 61000-6-3 |
Emission residential environments |
EN 61000-6-4 |
Emission industrial environments |
FCC part 15 |
Class B |
EN 50121-4 |
Railway signalling and telecommunications apparatus |
IEC 62236-4 |
Railway signalling and telecommunications apparatus |
• EMC specifications |
EN 61000-4-2, ESD |
Enclosure contact, ± 6 kV
Enclosure air, ± 8 kV |
IEC 61000-4-3, RF field AM modulated |
Enclosure:
20 V/m @ (80 – 2700) MHz
1 kHz sine, 80% AM |
ENV 50204, RF field 900 MHz |
Enclosure, 20 V/m pulse modulated 200 Hz, 900 ± 5 MHz |
EN 61000-4-4, fast transients |
Signal ports, ± 2 kV
Power ports, ± 2 kV |
EN 61000-4-5, surge |
Signal ports unbalanced, ± 2 kV line to earth, ± 2 kV line to line
Signal ports balanced, ± 2 kV line to earth, ± 1 kV line to line
Power ports, ± 2 kV line to earth, ± 2 kV line to line |
EN 61000-4-6, conducted RF immunity |
Signal ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz |
EN 61000-4-8, power frequency magnetic field |
Enclosure, 100 A/m, 50 Hz, 16.7 Hz & 0 Hz |
EN 61000-4-9, pulsed magnetic field |
Enclosure, 300 A/m, 6.4 / 16 μs pulse |
EN 61000-4-11, Voltage dips and interruption |
AC power ports:
10 & 5 000 ms, interruption
10 & 500 ms, 30% reduction
100 & 1 000 ms, 60% reduction |
EN 61000-4-16, Mains freq. 50 Hz |
Signal ports, 100 V 50 Hz line to earth |
SS 436 15 03, Mains freq. 50 Hz |
Signal ports, 250 V 50 Hz line to line |
EN 61000-4-29, voltage dips and interruption |
DC power ports:
10 & 100 ms, interruption
10 ms, 30% reduction
10 ms, 60% reduction
+20% above & –20% below rated voltage |
EN 55022, radiated RF emission |
Class B |
FCC part 15, radiated RF emission |
Class B |
FCC part 15, conducted emission |
AC power ports, class B |
EN 55022, conducted emission |
AC power ports, class B
PSTN, class B
DC power ports, class B |
• Safety |
Safety |
UL/IEC/EN 60950-1, IT equipment |
EN 60950-1, dielectric strength |
Signal port to other isolated ports, 2 kVrms 50 Hz 1 min
Power port to other isolated ports:
3 kVrms 50 Hz 1 min
2 kVrms 50 Hz 1 min (@ rated power <60 V) |
• Climatic |
Temperature, operating |
–25 to +70°C (–13 to +158°F) |
Temperature, storage |
–40 to +70°C (–40 to +158°F) |
Humidity, operating |
5 to 95% relative humidity non condensing |
Humidity, storage |
5 to 95% relative humidity non condensing |
• Enclosure |
Enclosure |
5 to 95% relative humidity non condensing |
Dimensions (W x H x D) |
34 x 123 x 121 mm (1.33 x 4.84 x 4.76 in) |
Weight |
0.21 kg |
Degree of protection |
IP 21 |
Cooling |
Convection |
Mounting |
Horizontal on 35 mm DIN-rail |
• Mechanical |
IEC 60068-2-6, vibration |
Operating:
7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz |
IEC-60068-2-27, shock |
Operating, 15 g, 11 ms |
• Interface specifications, power |
Rated voltage |
12 to 483427 VAC |
Operating voltage |
10 to 60 VDC
10 to 42 VDC |
Rated current |
150 mA @ 12 VDC
70 mA @ 24 VDC
40 mA @ 48 VDC
150 mA @ 12 VAC
70 mA @ 24 VAC |
Rated frequency |
DC: –
AC: 48 – 62 Hz |
Inrush current |
0.45 A²s |
Startup current |
0.30 Apeak |
Polarity |
Polarity independent |
Isolation to |
All other ports 3 kVrms 50 Hz 1 min |
Connection |
Detachable screw terminal |
Connector size |
0.2 – 2.5 mm2 (AWG 24 – 12) |
Shielded cable |
Not required |
• Public Switch Telephone Network (PSTN) |
Electrical specification |
Public Switched Telephone Network |
Data rate |
300 bit/s – 33.6 kbit/s |
Protocol |
Bell103, Bell212, V.21, V.22, V.22Bis, V.23C, V.32, V.32Bis, V.34, V.90 |
Protection |
Installation Fault Tolerant (up to ±60 V) |
Isolation to |
Power port, 3 kVrms 50 Hz 1 min
RS-232, 2 kVrms 50 Hz 1 min |
Connection |
RJ-11C |
Shielded cable |
Not required |
• Interface specifications, RS-232 |
Electrical specification |
EIA/TIA-232 |
Data rate |
1 200 bit/s – 115.2 kbit/s |
Data format |
7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits; Σ 9 – 12 bits |
Protocol |
Transparent |
Retiming |
Yes |
Transmission range |
Cable length ≤15 m / 49 ft |
Isolation to |
Power port, 3 kVrms 50 Hz 1 min
PSTN Line, 2 kVrms 50 Hz 1 min |
Connection |
9-pin D-sub female (DCE) and Detachable screw terminal (DCE) |
Shielded cable |
Not required |
Conductive housing |
Isolated to all other circuits |